구분 | JMC-9 | JMC-12 | JMC-18 | JMC-22 | JMC-32 | JMC-40 | JMC-48 | JMC-50 | JMC-65 | JMC-75 | JMC-85 | |||
정격 KSC 4504 |
3상 농형 모터 |
AC 3급 |
200~220V | 2.2kW 11A | 2.7kW 13A | 3.7kW 18A | 4kW 20A | 5.5kW 26A | 7.5kW 35A | 11kW 48A | 11kW 50A | 15kW 65A | 18.5kW 75A | 19kW 80A |
380~440V | 2.7kW 7A | 4kW 9A | 5.5kW 13A | 7.5kW 20A | 11kW 25A | 15kW 32A | 15kW 35A | 22kW 48A | 30kW 65A | 37kW 75A | 37kW 80A | |||
500~550V | 2.7kW 6A | 5.5kW 9A | 5.5kW 13A | 7.5kW 17A | 11kW 20A | 15kW 26A | 15kW 28A | 22kW 38A | 37kW 60A | 37kW 64A | 45kW 75A | |||
AC 4급 |
200~220V | 1.5kW 8A | 2.2kW 11A | 3.7kW 18A | 3.7kW 18A | 4.5kW 20A | 5.5kW 25A | 7.5kW 30A | 7.5kW 35A | 11kW 50A | 13kW 55A | 15kW 65A | ||
380~440V | 2.2kW 6A | 4kW 9A | 4kW 9A | 5.5kW 13A | 7.5kW 17A | 11kW 24A | 11kW 28A | 15kW 32A | 22kW 47A | 25kW 52A | 30kW 62A | |||
단상모터 | 110V | 0.4kW 11A | 0.5kW 13A | 0.75kW 18A | 0.9kW 20A | 1.2kW 26A | 1.7kW 35A | - | - | - | - | - | ||
220V | 0.8kW 11A | 1kW 13A | 1.5kW 18A | 1.8kW 20A | - | - | - | - | - | - | - | |||
저항 부하 DC 1급 |
2극 직렬 |
110V | 6A | 10A | 13A | 15A | 25A | 25A | 25A | 35A | 35A | 50A | 50A | |
220V | 3A | 7A | 8A | 12A | 12A | 12A | 12A | 15A | 15A | 20A | 20A | |||
3극 직렬 |
110V | 8A | 12A | 18A | 20A | 25A | 35A | 35A | 50A | 65A | 70A | 80A | ||
220V | 8A | 12A | 18A | 20A | 22A | 30A | 30A | 40A | 50A | 55A | 60A | |||
통전전류(AC1급) | 25A | 25A | 40A | 40A | 50A | 60A | 70A | 80A | 100A | 110A | 135A | |||
IEC 60947 |
3상 농형 모터 |
AC 3급 |
200~220V | 2.5kW 11A | 3.5kW 13A | 4.5kW 18A | 5.5kW 22A | 7.5kW 32A | 11kW 40A | 11kW 48A | 15kW 55A | 18.5kW 65A | 22kW 75A | 25kW 85A |
380~440V | 4kW 9A | 5.5kW 12A | 7.5kW 18A | 11kW 22A | 15kW 32A | 18.5kW 40A | 18.5kW 45A | 22kW 50A | 30kW 65A | 37kW 75A | 45kW 85A | |||
500~550V | 4kW 7A | 7.5kW 12A | 7.5kW 13A | 15kW 22A | 18.5kW 28A | 22kW 32A | 22kW 40A | 30kW 43A | 37kW 60A | 45kW 64A | 45kW 75A | |||
690V | 4kW 5A | 7.5kW 9A | 7.5kW 9A | 15kW 18A | 18.5kW 20A | 22kW 23A | 22kW 25A | 30kW 28A | 33kW 35A | 37kW 42A | 45kW 45A | |||
수명 (만회) |
전기적 | 250 | 250 | 250 | 250 | 200 | 200 | 200 | 200 | 200 | 200 | 200 | ||
기계적 | 2500 | 2500 | 2500 | 2500 | 1500 | 1500 | 1500 | 1000 | 1000 | 1000 | 1000 | |||
보조접점 (표준) | 1a1b | 1a1b | 1a1b | 1a1b | 2a2b | 2a2b | 2a2b | 2a2b | 2a2b | 2a2b | 2a2b | |||
부착방식 | 나사 · 레일 설치 겸용 | |||||||||||||
외형치수(mm) (WxHxD) | 43.8 x 79.9 x 86.5 | 68 x 82 x 94.3 | 94 x 123.6 x 117 | |||||||||||
부착치수(mm) (가로x세로) | ![]() ![]() |
![]() ![]() |
진흥홈피
'전기' 카테고리의 다른 글
접지저항 측정방법 (0) | 2009.02.22 |
---|---|
[스크랩] 신 국제규격 전선의 허용전류표 (0) | 2009.02.22 |
누전차단기 기술자료 <LS산전> (0) | 2009.02.22 |
절연저항 테스터 사용법 [메가] (0) | 2009.02.22 |
아파트 누전잡기 | (0) | 2009.02.22 |